www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 10 - 4 10 - 4 Fault Finding Air Conditioning - System Diagnosis (cont'd) Low R-134a Charge Gauge Readings: Low Side Gauge - Low. High Side Gauge - Low. Other symptoms: Sight Glass - Bubbles continuously visible. Diagnosis: System slightly low on R-134a, due to leak or incorrect charge. Correction: 1. Leak test system. 2. Evacuate A/C system. 3. Repair system leaks. 4. Charge system with R-134a. 5. Operate system and check performance.
LOW SIDE (Blue) HIGH SIDE (Red) Low Low 60 7 0 3501201101000908 150 2 0 0 250 20304050 350003 100 50 400 10 0 0 3 0 450 500 A268030 LOW SIDE - 0.76 bar (0.77 kgf/cm2)(11 lbf/in2) HIGH SIDE - 8.3 bar (8.5 kgf/cm2)(121 lbf/in2) Poor Refrigerant Circulation Gauge Readings: Low Side Gauge - Zero to negative. High Side Gauge - Low. Other symptoms: Receiver-Drier - Frost on tubes from receiver-drier to evaporator unit. Diagnosis: Refrigerant flow obstructed by dirt, receiver-drier clogged. Correction: 1. Evacuate A/C system. 2. Replace receiver-drier. 3. Charge system with R-134a. 4. Operate system and check performance.
LOW SIDE (Blue) HIGH SIDE (Red) Zero to negative Low 60 7 0 3501201101000908 150 2 0 0 250 20304050 350003 100 50 400 10 0 0 3 0 450 500 A268040 LOW SIDE - -1.0 bar (-1.1 kgf/cm2)(-15 lbf/in2) HIGH SIDE - 5.4 bar (5.5 kgf/cm2)(78 lbf/in2)