Komatsu PC210-6K — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE 24.2 WHEN REQUIRED 24.2.1 CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT A WARNING e Never clean or replace the air cleaner element with the engine running. e When using pressure air to clean the element glasses or goggles to protect the eyes. wear safety Checking if air cleaner element. clogging monitor @) flashes, clean the air cleaner NOTICE Do not clean the element before the air cleaner clogging monitor on the monitor panel flashes. If the element is cleaned frequently before the clogging monitor flashes, the air cleaner cannot display its full ability, and the cleaning efficiency will be lowered.

In addition, if the element is cleaned more frequently, the dust sticking to the element will drop into the inner element more frequently. Cleaning or replacing outer element 1. Open the front door on the left side of the machine, remove wing nut @ and take out element @. To prevent entry of dirt and dust, cover the air connector side of the rear end of the air cleaner with a clean cloth and adhesive tape. 2. 3. Clean the air cleaner body Direct dry compressed interior and the cover. air (less than 700 kPa (7 kg/cm, to element @ from inside along its folds, then outside along its folds and again from inside.

1) 2) 3) 4) 3-26 100 psi)) direct it from Remove one seal from the outer element whenever the outer element has been cleaned. Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. Replace both inner and outer elements when the monitor lamp @ flashes soon after installing the cleaned outer element even though it has not been cleaned 6 times. Check inner element mounting nuts for looseness and, if necessary, retighten. AD053020