Komatsu PC210-6K — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE 24.2.10 CHECK AND ADJUST AIR CONDITIONER CHECK LEVEL OF REFRIGERANT (GAS) AWARNING e When repairing or inspecting the air conditioner, be sure to handle the refrigerant gas according to regulations of your country. e If the liquid gets into your eyes or on your hands, it may cause loss of sight or frostbite, so never loosen any part of the refrigerant circuit. If there is a lack of refrigerant (Freon 134a), the cooling performance will be poor. When operating the cooler at high speed, there should be no bubbles in the sight glass (inspection window) mounted on the condenser unit receiver. e No bubbles in refrigerant flow:

Correct e Bubbles in refrigerant flow (bubbles continuously pass through): Refrigerant level low e Colorless, transparent: , AN114640 Sight glass Correct BE No refrigerant >°*.\ Refrigerant “S7 REMARK When there are bubbles, the refrigerant gas level is low, so contact your refrigerant dealer to have refrigerant added. If the air conditioner is run with the refrigerant gas level low, it will cause damage to the compressor. Check in off-season When not being used for a long period, operate the cooler for 3 to 5 minutes once a month to supply lubricant to each component of the compressor.

Inspection and maintenance items Inspection and maintenance items list for cooler Contents Maintenance interval Refrigerant (gas) Filling quantity Twice a year; spring and autumn Condenser Clogging Every 500 hours Compressor Function V belt Damage Blower motor Function (Check for and fan abnormal Control mechanism Piping for connection 3-42 of fin Every 4000 and tension sound) Functi Check for unction ( . normal function) Installation condition looseness of tightening) connection portions gas leakage, damage hours Every 250 hours Wh ired en require When . required When required level low No refrigerant olorless, transparent) Receiver AD053280