24. SERVICE PROCEDURE 24.2.11 REPLACE ADDITIONAL ELEMENT BREAKER FILTER AWARNING Immediately after operating the engine, all parts still retain high temperature. Never replace the filter in sucn condition. Replace it only after each part has sufficiently cooled. AN114650 @ Prepare a container for draining off oil. 1. Place the container under the filter element. 2. Turn filter case G) counterclockwise to remove it. Remove ele- ment @ from the case. 3. Unscrew plug @ from filter case @). 4. Clean the removed parts. Mount a new element @ and O-ring @. 5. After the case reaches the filter holder, case by more than a 1/2 turn.
additionally tighten the AN114660 NOTICE 5000 (H) When the breaker is used, replace the element every approx. 250 hours (when operating ratio is more than 50%), referring to the chart at the right. lf the machine is equipped with the hydraulic breaker, be sure to install an additional filter to the return circuit. interval e@ “l 3000 Replacement interval (or Praraulie oil ce o = o oO a ‘a @ ce 2000 $000 — Additional filter element 500 0 When ot j using breaker, Hydraulic element 20 +250 40 60 80 100 Breaker operating ratio (& When using filter breaker only) AW35414B 3-43