Komatsu PC210-6K — 11.1 MACHINE MONITOR

11, EXPLANATION OF COMPONENTS AIR CLEANER CLOGGING This warns that the air cleaner is clogged. If the monitor lamp flashes, stop the engine, then inspect and clean the air cleaner. ‘ele 3. AD313370 11.1.3 C: EMERGENCY STOP ITEMS A CAUTION lf any monitor lamp flashes, stop the engine idling, and take the following action. 1. ENGINE WATER or run it at low TEMPERATURE If the temperature of the engine cooling water becomes abnormally high, the monitor lamp flashes, and the overheat prevention system is automatically actuated to reduce the engine speed. Stop operations and run the engine at low idling until the engine water temperature gauge enters the green range. AD313390 2.

RADIATOR WATER LEVEL if the radiator water level drops, the monitor lamp flashes. Stop the engine, check the radiator water level, and add water if necessary. AD3 14020 3. ENGINE OIL PRESSURE if the engine oil pressure drops below the normal pressure, the monitor lamp flashes. At this item, stop the engine and inspect it according to “16.6 OTHER TROUBLE.” REMARK While the starting switch off once the engine is ON, the lamp is started. When remains lit and goes the engine starts, the buzzer may sound for a short time, however, this does not indicate a fault. AD313410