TESTING AND ADJUSTING FUEL SYSTEM (CALIBRATION DATA) Injection Pump Assembly Number 615002 12-12-3 8 5 12-12-3 9 12-12-3 (10) 6151-72-1770 (106692-9260) Applicable Machine Applicable Engine 6151-72-1771 (106692-9261) 6151-72-1860 (106069-7270) (–50°C) Model Serial No. Model Serial No. ( ): Injection pump manufacturer’s part No.
D85A-21, D85E-21 S6D125-2 Injection Injection pump D85P-21, D85C-21 Pump Type Manufacturer D85A-21S, D85A-21B D85A-21D PE-P(PS3S) BOSCH Injection pump specification Engine Specification Rotating direction Counterclockwise Flywheel horsepower (kW {HP}) / rpm) 177 {222}/2,000 (Gross) Injection order 1 – 5 – 3 – 6 – 2 – 4 Maximum torque (Nm {kgm}/ rpm) 1,040 {106}/1,400 (Gross) Injection interval 59°30’ – 60°30’ High idling speed (rpm) 2,150 – 2,250 Plunger pre-stroke (mm) 3.70 – 3.80 Low idling speed (rpm) 670 – 720 Delivery valve (mm3/st) 90 Pump tester capacity retraction volume Motor 7.5 kW for Service standard Calibration Standard ( ):
Injection pump manufacturer’s part number Applicable Engine Serial No. Model Serial No. S6D125-2 Conditions Nozzle & nozzle holder p Nozzle part No. ‡ Service standard indicates data Nozzle holder part No. using calibration Injection pipe test parts. (Outside dia. x inside dia. x ‡ Manufacturer Test oil standard is data Oil temperature for factory test. Nozzle opening pressure (MP Transfer pump pressure (kP Service standard Manufacturer standard Nozzle & nozzle holder p art No. (105780-8140) 6151-12-3200 (105111-4550) Nozzle part No. (105780-0000) 6151-12-3220 (105025-0330) Nozzle holder part No. (105780-2080) 6152-12-3110 (105041-7130) Injection pipe (Outside dia. x inside dia.
x (mm) 8 x 3 x 600 length) 6 x 2.2 x 720 Test oil ASTM D975 No. 2 diesel fuel or equivalent Oil temperature (°C) 40 to 45 Nozzle opening pressure (MP a{kg/cm2}) 17.2 {175} 24.5 {250} Transfer pump pressure (kP a{kg/cm2}) 157 {1.6} 157 {1.6} Injection volume ‡ Rack positions B to E are the reference volume when adjusting the injection volume.
Rack Rack position point (mm) Service standard (cc/1000 st.) Pump speed Average Maximum (rpm) injection variance quantity between cylinder Manufacturer standard (cc/ st.) Maximum variance between cylinder Average injection quantity b Maximum variance etween cylinder A 9.1 (Basic point) 1,000 fl119 – 123 ±3 fl145 – B 9.3 700 fl142.5 – 146.5 ±4 fl167 – C Approx. 6.0 400 – ±15 fl16 – E – 100 fl185 – 205 – fl200 – Z Approx. 6.0 540 – – – – Governor performance curve Boost compensator performance curve Rotating direction Countercl Injection order 1 – 5 – 3 – Injection interval 59°30’ – Plunger pre-stroke (mm) 3.70 – Delivery valve (mm3/st) retraction volume 90