TESTING AND ADJUSTING FUEL SYSTEM (CALIBRATION DATA) 615002 615002 12-12-21 8 12-12-21 (10) Injection Pump Assembly Number Applicable Machine Applicable Engine 6151-72-1570 (106692-9360) Model Serial No. Model Serial No. ( ): Injection pump manufacturer’s part No.
CS210-1 S6D125-2 Injection Injection pump Pump Type Manufacturer PE-P(PS3000) BOSCH Injection pump specification Engine Specification Rotating direction Counterclockwise Flywheel horsepower (kW {HP}) / rpm) 163 {218}/2,000 (Gross) Injection order 1 – 5 – 3 – 6 – 2 – 4 Maximum torque (Nm {kgm}/ rpm) 954 {97.3}/1,300 (Gross) Injection interval 60° ± 30’ High idling speed (rpm) 2,200 ± 50 Plunger pre-stroke (mm) 3.75 ± 0.75 Low idling speed (rpm) 650+50 +0 Delivery valve (mm3/st) 60 Pump tester capacity retraction volume Motor 7.5 kW for Service standard Calibration Standard ( ): Injection pump manufacturer’s part number Applicable Engine Serial No. Model Serial No.
S6D125-2 Conditions Nozzle & nozzle holder pa Nozzle part No. ‡ Service standard indicates data Nozzle holder part No. using calibration Injection pipe test parts. (Outside dia. x inside dia. x le ‡ Manufacturer Test oil standard is data Oil temperature for factory test. Nozzle opening pressure (MPa{ Transfer pump pressure (kPa{ Service standard Manufacturer standard Nozzle & nozzle holder pa rt No. (105780-8140) 6151-12-3400 (105111-4600) Nozzle part No. (105780-0000) 6151-12-3420 (105025-0750) Nozzle holder part No. (105780-2080) 6152-12-3110 (105041-7130) Injection pipe (Outside dia. x inside dia. x le (mm) 8 x 3 x 600 ngth) 6 x 2.2 x 720 Test oil ASTM D975 No.
2 diesel fuel or equivalent Oil temperature (°C) 40 to 45 Nozzle opening pressure (MPa{ kg/cm2}) 17.2 {175} 24.5 {250} Transfer pump pressure (kPa{ kg/cm2}) 157 {1.6} 157 {1.6} Injection volume ‡ Rack positions B to E are the reference volume when adjusting the injection volume. ‡ Marks fl are average volumes. Rack point Rack P position s (mm) ( Service standard (cc/1000 st.) ump peed Maximum rpm) Injection variance volume between cylind Manufacturer standard (cc/1000 st.) Maximum variance between cylind Injection er volume Maximum variance between cylinder A (Basic poin 8.6 1 t) ,000 fl114 ± 2 ±3 fl133 – B 8.6 650 fl132 ± 3 ±4 fl147.5 – C Approx.
6.0 325 fl15 ± 1.5 ±15 fl15 – E – 100 fl145+20 +0 – fl150 – Governor performance curve Boost compensator performance curve Rotating direction Counterclockwise Injection order 1 – 5 – 3 – 6 – 2 – 4 Injection interval 60° ± 30’ Plunger pre-stroke (mm) 3.75 ± 0.75 Delivery valve (mm3/st) retraction volume 60