TESTING AND ADJUSTING FUEL SYSTEM (CALIBRATION DATA) 615002 12-12-22 8 12-12-22 (10) Injection Pump Assembly Number Applicable Machine Applicable Engine 6152-72-1250 (106675-4503) Model Serial No. Model Serial No. ( ): Injection pump manufacturer’s part No.
PC400-6 (CUSTOM) 32001 and up SA6D125-2 Injection Injection pump PC400LC-6 (CUSTOM) 32001 and up Pump Type Manufacturer PC450-6 (MIGHTY) 12001 and up PC450LC-6 (MIGHTY) 12001 and up PE-P(PS3S) ZEXEL Injection pump specification Engine Specification Rotating direction Counterclockwise Flywheel horsepower (kW {HP}) / rpm) 241 {322}/2,050 (Gross) Injection order 1 – 5 – 3 – 6 – 2 – 4 Maximum torque (Nm {kgm}/ rpm) 1,240 {126}/1,400 (Gross) Injection interval 59°30’ – 60°30’ High idling speed (rpm) 2,200 – 2,300 Plunger pre-stroke (mm) 3.75 – 3.85 Low idling speed (rpm) 675 – 725 Delivery valve (mm3/st) 100 Pump tester capacity retraction volume Motor 7.5 kW for Service standard Calibration Standard ( ):
Injection pump manufacturer’s part number Applicable Machine Applicable Engine Model Serial No. Model Serial No. PC400-6 (CUSTOM) PC400LC-6 (CUSTOM) PC450-6 (MIGHTY) PC450LC-6 (MIGHTY) 32001 and up 32001 and up 12001 and up 12001 and up SA6D125-2 Conditions Nozzle & nozzle holder part No. Nozzle part No. ‡ Service standard indicates data Nozzle holder part No. using calibration Injection pipe (mm test parts. (Outside dia. x inside dia. x length) ‡ Manufacturer Test oil standard is data Oil temperature (°C for factory test.
Nozzle opening pressure (MPa{kg/cm2}) Transfer pump pressure (kPa{kg/cm2}) Service standard Manufacturer standard (105780-8140) 6152-12-3100 (105111-4540) (105780-0000) 6152-12-3120 (105025-0120) (105780-2080) 6152-12-3110 (105041-7130) ) 8 x 3 x 600 6 x 2.2 x 720 ASTM D975 No. 2 diesel fuel or equivalent ) 40 to 45 17.2 {175} 27.5 {280} 157 {1.6} 157 {1.6} Injection volum ‡ Rack positions B to E are the reference volum when adjusting the injection volume.
e Rack point e A (Basic point) B C D E Rack position (mm) Pump speed (rpm) Service standard (cc/1000 st.) Average Maximum injection variance quantity between cylinder Manufacturer standard (cc/1000 st.) Maximum variance between cylinder Average injection quantity Maximum variance between cylinder 9.4 1,015 173 – 177 ±3 182.5 – 9.4 1,025 172 – 175 – 182.5 – 9.4 700 171.5 – 177.5 – 181.5 – Approx.
5.7 350 11.5 – 14.5 ±15 15 – – 100 155 – 175 – 160 – Governor performance curve Rotating direction Counterclockwise Injection order 1 – 5 – 3 – 6 – 2 – 4 Injection interval 59°30’ – 60°30’ Plunger pre-stroke (mm) 3.75 – 3.85 Delivery valve (mm3/st) retraction volume 100 wheel horsepower (kW {HP}) / rpm) 241 {322}/2,050 (Gross) aximum torque (Nm {kgm}/ rpm) 1,240 {126}/1,400 (Gross) gh idling speed (rpm) 2,200 – 2,300 w idling speed (rpm) 675 – 725 mp tester capacity Service standard Motor 7.5 kW