Drop of Electric Pressure Test of Alternator Output Wire This test is to check that wiring is correctly connected between the alternator “B“ terminal and battery (+) terminal. Preparation 1. Turn the ignition switch OFF. 2. Disconnect the battery ground cable. 3. Disconnect the alternator output wire from the alternator “B” terminal. 4. Connect a DC ampere meter (0-100A) between the terminal and the disconnected output wire. Connect (+) lead wire to the terminal “B” and (-) lead wire to the disconnected output wire. NOTE: In case of using a clamp type ammeter, it is possible to measure current without disconnecting the harness. 5.
Connect a digital voltmeter between the alternator “B” terminal and the battery (+) terminal. Connect (+) lead wire to the terminal and (-) lead wire to the battery (+) terminal. 6. Connect the battery ground cable. 7. Be sure that the hood is opened. Test 1. Start the engine. 2. Repeating ON and OFF of headlight and small light, adjust the engine speed until an ammeter reads 20A and at that time measure voltage. Result 1. If voltmeter reading is within the standard, it is normal. 2. If voltmeter reading is more than the standard, mostly wiring is faulty.
In this case, inspect wirings between the alternator and the battery (+) terminal as well as between the alternator “B” terminal and the fusible link. 3. Also prior to re-test, check and repair the connecting part for looseness and the harness for discoloration by overheating. 4. After test, adjust the engine speed at idle and turn the light and ignition switch OFF. 5. Disconnect the battery ground cable. 6. Disconnect the ammeter and voltmeter. 7. Connect the alternator output lead wire to the alternator “B” terminal. 8. Connect the battery ground cable. Output Current Test This test is to check that the alternator output current is identified with the rated current. Preparation 1.
Prior to test, inspect the following items and repair if necessary. 1) Be sure that the battery installed in the vehicle is normal. (See “Battery”) NOTE: When measuring output current, necessarily use a slightly discharged battery. Fully charged battery is not enough to use for correct test owing to insufficient load. 2) Inspect the drive belt for tension. (See “Engine body” ) G643(E) Service Manual Chapter 4. Engine Electrical System 132