Limp Home Mode The system is capable of "limp-home" mode in the event of particular faults or failures in the system. In limp-home mode the engine speed is approximately 1000 rpm at no load. A variety of fault conditions can initiate limp-home mode. These fault conditions and resulting actions are determined during calibration and are OEM customer specific. Service Tool A scan tool/monitoring device is available to monitor system operation and assist in diagnosis of system faults This device monitors all sensor inputs, control outputs, and diagnostic functions in sufficient detail through a single access point to the SECM to allow a qualified service technician to maintain the system.
This Mototune software (licensed by Mototron Communication) is secure and requires a crypt- token USB device to allow access to information. LPG Fuel System Operation The principles outlined below describe the operation of MI-07 on an LPG fuel system. An LPG fuel system consists of the following components: • Fuel filter (supplied by customer) • Electric fuel lock-off solenoid valve • Fuel pressure regulator/vaporizer • Gas/Air mixer • Miscellaneous customer-supplied hoses and fittings Fuel is stored in the customer-supplied LPG tank in saturated liquid phase and enters the fuel system from the tank as a liquid and at tank pressure.
Fuel passes through a high-pressure fuel filter and lock- off solenoid, and is then vaporized and regulated down to the appropriate pressure to supply the mixer. The regulator controls the fuel pressure to the gas/air mixer. The mixer meters fuel delivery based upon airflow into the engine. SECM The Small Engine Control Module (SECM) controls the LPG lock-off solenoid valve. The lock-off solenoid is energized when fueling with LPG and the engine is turning. The lock-off is de-energized when engine rpm is not detected. MI-07 LP Fuel Filter The LP fuel filter of G643 engine is the same as that of G643E engine.
See, “G643E EMS overview” MI-07 Fuel Lock-Off (Electric) The LP fuel lock-off of G643 engine is the same as that of G643E engine. See, “G643E EMS overview” N-2001 Regulator/Converter After passing through the electric fuel lock-off, liquid propane enters the N-2001 regulator/converter (Figure 4). The N-2001 functions as a fuel vaporizer, converting liquid propane to vapor propane and as a two-stage negative pressure regulator, supplying the correct vapor propane fuel pressure to the mixer. The regulator is normally closed requiring a vacuum signal (negative pressure) to allow fuel to flow. This is the second of three safety locks in the MI-07 system.
If the engine stops, vacuum signal stops and fuel flow will automatically stop when both the secondary (2nd stage) valve and the primary (1st stage) valve closes. Unlike most other regulator/converters, the N-2001 primary valve closes with fuel pressure rather than against pressure, extending primary seat life and adding additional safety. Figure 4. N-2001 Regulator Liquid propane must be converted into a gaseous form in order to be used as a fuel for the engine. When the regulator receives the desired vacuum signal it allows propane to flow to the mixer.
As the propane flows through the regulator the pressure is reduced in two stages from tank pressure to slightly less than atmospheric pressure. As the pressure of the propane is reduced the liquid propane vaporizes and refrigeration occurs inside the regulator due to the large temperature drop inside the regulator from the vaporization of liquid propane. To replace heat lost to vaporization, engine coolant is supplied by the engine driven water pump and pumped through G643(E) Service Manual Chapter 5. Engine Management System (EMS) 171