Figure 34. Secondary Stage Test Connection Pressure Test Primary Stage Test Hardware 1. Shop air pressure regulator adjusted to 100 psi 2. Shop air hose fitting (1/4” NPT to air hose) 3. Air hose 4. Test gauge fitting (1/16” NPT x 1/4” hose barb) 5. Vacuum hose or vinyl tubing 6. 0-60” WC Magnehelic gauge (inches of water column) Primary Stage Pressure Test 1. Remove the primary test port plug from the side of the regulator and install the 1/16” NPT hose barb fitting (Figure 35). 2. Connect a compressed air line (shop air ~100psi) to the liquid propane fuel inlet of the N-2007 regulator (Figure 35). Figure 35. Primary Stage Test Connection 3.
Apply compressed air, wait for air to exit the hose barb in the test port, and then connect the Magnehelic gauge (Figure 36) to the hose barb using the vacuum hose or vinyl tubing. This prevents the gauge from reading maximum pressure due to the large velocity of compressed air entering the primary chamber. 4. Make sure there is no leakage at any of the fittings. The static pressure should read between 40-60” of water column on the Magnehelic gauge and maintain a constant pressure for 60 seconds. Figure 36. Magnehelic Gauge Connection to Hose Barb 5.
If the pressure reading begins to increase, a leak is most likely present at the primary valve, either the primary valve o-ring or the valve itself. If a leak is present the regulator should be replaced. 6. If the pressure begins to decrease, the secondary seat is probably not making an adequate seal and is leaking. The regulator should be replaced. 7. If the test is successful, re-install the primary test port plug and check the fittings for leaks. See Chapter 5 for installation of the N-2007 regulator. NOTE : The N-2007 primary stage pressure can also be tested at idle on a running engine.
The N- 2007 primary pressure should be between 40 inH20 (99.6mbar) and 55 inH20 (137 mbar) at 750 rpm, idle. G643(E) Service Manual Chapter 6. LPG FUEL DELIVERY SYSTEM 200