Doosan G643 LP Engine — Doosan G643 LP Engine User Manual

Electrical Circuit Inspection Procedure • Check Open Circuit normal). To find exact break point, check sub line of line 1as described in next step. 1. Procedures for Open Circuit Continuity Check Voltage Check If an open circuit occurs (as seen in [FIG.1]), it can be found by performing Step 2 (Continuity Check) or Step 3 (Voltage Check Method) as shown below. 2. Continuity Check Method NOTE: When measuring for resistance, lightly shake the wire harness above and below or from side to side. Specification (Resistance) 1 Ω or less Normal Circuit 1 or Higher Open Circuit b.

Disconnect connector (B), and measure for resis tance between connector (C) and (B1) and between (B2) and (A) as shown in [FIG.3]. In this case the measured resistance between connector (C) and (B1) is higher than 1 and the open circuit is between terminal 1 of connector (C) and terminal 1 of connector (B1). 3. Voltage Check Method a. With each connector still connected, measure the voltage between the chassis ground and terminal1 of each connectors (A), (B) and (C) as shown in [FIG.4]. The measured voltage of each connector is 5V, 5V and 0V respectively. So the open circuit is between connector (C) and (B). a.

Disconnect connectors (A), (C) and measure resistance between connector (A) and (C) as shown in [FIG.2]. In [FIG.2.] the measured resistance of line1and 2 is higher than 1 and below 1 Ω respectively. Specifically the open circuit is line 1(Line 2 is G643(E) Service Manual 232 Chapter 7. Basic Troubleshooting