• Check Short Circuit b. Disconnect connector (B), and measure the resistance between connector (A) and chassis ground, and between (B1) and chassis ground as shown in [FIG.7]. The measured resistance between connector (B1) and chassis groundis1 Ω or less. The short to ground circuit is between terminal 1 of connector (C) and terminal 1 of connector (B1). 1. Test Method for Short to Ground Circuit Continuity Check with Chassis Ground If short to ground circuit occurs as shown in [FIG.5], the broken point can be found by performing below Step 2 (Continuity Check Method with Chassis Ground) as shown below. 2. Continuity Check Method (with Chassis Ground) NOTE:
Lightly shake the wire harness above and below, or from side to side when measuring the resistance. Specification (Resistance) 1 Ω or less Short to Ground Circuit 1 or Higher Normal Circuit a. Disconnect connectors (A), (C) and measure for resistance between connector (A) and Chassis Ground as shown in [FIG.6]. The measured resistance of line 1 and 2 in this example is below 1 Ω and higher than 1 respectively. Specifically the short to ground circuit is line 1 (Line 2is normal). To find exact broken point, check the sub line of line1 as described in the following step. G643(E) Service Manual 233 Chapter 7. Basic Troubleshooting