Rough, Unstable, Incorrect Idle, or Stalling (cont’d.) Related MIL Faults: EST faults ETC Sticking fault Pre-catalyst adapts error G643(E) Service Manual 243 Chapter 7. Basic Troubleshooting PROBABLE CAUSE CORRECTIVE ACTION Excess flow valve closed Reset excess flow valve. • Close liquid valve. • Wait for a “click” sound. Slowly open liquid valve. Clogged fuel filter Repair/replace as required See Chapter 2 Fuel Filter Replacement Plugged fuel line Remove obstruction from the fuel line. • Close liquid fuel valve. • Using caution, disconnect the fuel line (some propane may escape). • Clear obstruction with compressed air. • Re-connect fuel line. • Slowly open liquid fuel valve & leak test.
Fuel lock-off malfunction Repair/replace fuel lock-off. See Chapter 2 Fuel Lock-Off. Faulty vapor connection between the pressure regulator/converter and the mixer Check connection. • Verify no holes in hose. • Clamps must be tight. • Look for kinked, pinched and/or collapsed hose. Pressure regulator freezes Check level in cooling system: • Must be full, check coolant strength • -35°F (-37°C) minimum Check coolant hoses. • Watch for kinks and/or pinched hoses. • Verify one pressure hose and one return hose. Test regulator. See Chapter 6 Vacuum leak Check for vacuum leaks. • Between mixer and throttle body • Between throttle body and intake manifold • Between intake manifold and cylinder head