Flywheel Runout For checking procedure, see Flywheel And Flywheel Housing in the Testing And Adjusting section. Face Runout (Axial Eccentricity). Maximum permissible face runout of the flywheel ................................................0.19 mm (.0075 in) Outside Diameter Runout (Radial Eccentricity) Pressure Cap For testing procedure, see Cooling System Tests in the Testing And Adjusting section. Pressure valve opening pressure .....................................85 to 110 kPa (12 to 16 psi) Vacuum valve opening pressure ........................................... 0 to 5 kPa (0 to 0.7 psi) Thermostat Full open temperature......
85 to 95 (185 to 195 ) Outside Diameter Runout Check Maximum permissible outside diameter runout of the flywheel .......................................... 0.1 mm (.004 in) G643 (E) Service Manual Chapter 3. Engine Mechanical System 37