Cold Weather Starting B3.9, B4.5, and B5.9 Industria [...] Page 1-10 Section 1 - Operating Instructions If the intake manifold air temperature is greater than 19°C [66°F], the electric grid air heater system will not be activated. If the intake manifold air temperature is below 19°C [66°F], the system will operate as follows: Engine Starting Cycle illuminated for approximately 25 seconds. Do not crank the engine until the WAIT-TO-START lamp shuts off. NOTE: The controller is reset each time the ignition is turned off and the cycle will start over. 1. Turn the ignition key to the RUN position. When the key is in this position, the WAIT-TO-START lamp will be Postheat Cycle 2.
When the WAIT-TO-START lamp goes out, the preheat cycle is complete. Crank the engine. 3. Postheating occurs as the grid heater elements are cycled for a while with the engine running. Postheating helps warm the engine up faster and eliminates white smoke. Postheating is determined by the intake manifold air temperature upon start-up.