B3.9, B4.5, and B5.9 Industria [...] Cold Weather Starting Section 1 - Operating Instructions Page 1-9 Ether Starting Aids Because of the potential for an explosion, do not use volatile cold starting aids in underground mine or tunnel operations. Ask the local U.S. Bureau of Mines inspector for instructions. WARNING Starting fluid is highly flammable and explosive. Keep flames, sparks, and arcing switches away from starting fluid. WARNING WARNING Do not breathe starting fluid fumes. Starting fluid fumes can be hazardous to your health. Do not use excessive amounts of starting fluid when starting an engine. The use of too much starting fluid will cause damage to the engine.
CAUTION Spray starting fluid into the air cleaner intake while another person cranks the engine. Grid Heater WARNING To reduce the possibility of personal injury and property damage, never use starting fluid if the grid heater option is used. Starting fluid, which contains ether, can cause an explosion. A grid heater is available that improves cold weather starting characteristics by heating the intake air. It can also serve to reduce white smoke if it is energized during cold ambient temperatures while the engine is at idle. The electric grid heater operates in a preheat and postheat mode. The length of heater on-time is a function of the engine temperature.