MAINTENANCE LUBRICATION Apply grease to the grease fitting shown by the arrow. 1. Center drive shaft spline (1 point) AIR DRYER - IF EQUIPPED Perform the following inspection of the air dryer and if there is any abnormality, contact your distributor. * Open the air tank drain valves and check that only a small amount of water is drained. Note that if the ambient temperature is lower than 16°C (61 “F), a small amount of water may be collected in the drain. * Check that there is no abnormal inclusion of oil in water drained from the exhaust port of the air dryer. EVERY 1000 HOURS SERVICE * Maintenance for every 50,100,250 and 500 hours should be carried out at the same time.
TRANSMISSION OIL AND STRAINER Operate the machine until the transmission oil reaches operating temperature. Park the machine on a level surface, apply the parking brake, lower the bucket to the ground and stop the engine. A 1. WARNING! Avoid direct contact of hot oil with your skin. Hot oil can cause personal injury. 2. Remove oil drain plug (P). After the oil has drained completely, reinstall and tighten the drain plug. * After loosening drain plug (P), pull out the plug slowly to prevent the oil from spouting out. 3. Replace the transmission oil filter element(s) as described under “TRANSMISSION OIL FILTER”. 3-62