Komatsu — Stabilized Open Circuit Voltage Test

MAINTENANCE 1. Using a hydrometer, extract electrolyte from each battery cell. Measure and record the specific gravity, corrected to 26.7”C (80°F) of each ceil. Compare the readings obtained with the following table to determine battery’s state of charge. Specific Gravity (Corrected to 26.7”C or 80°F) I State of Charge 1.265 Fully Charged 1.225 75% Charged 1.190 50% Charged 1.555 25% Charged 1.120 Discharged 2. If the specific gravity readings of all cells are 1.225 or higher and are within 50 points (0.050 specific gravity) between the highest and lowest cells, the battery is OK. 3.

If the specific gravity readings are below 1.225 or vary more than 50 points between the highest and lowest cells, recharge the battery. Inspect the electrical system to determine the cause for the under-charged battery. 4. If, after charging, the specific gravity readings are within 50 points between the highest and lowest cells, the battery is OK. If the readings still vary more than 50 points after charging, replace the battery. Stabilized Open Circuit Voltage Test NOTE: A service tool is required for this test. If the battery has just been recharged or has been in vehicle service, the surface charge must be removed before an accurate voltage measurement can be made.

Do this by turning “ON” the high beam headlights for fifteen (15) seconds or by placing a 15 ampere load across the battery terminals for fifteen (15) seconds. Turn “OFF” the lights or remove the load, then let the battery stand for at least three (3) minutes to stabilize voltage. Connect a Voltmeter or Electronic Battery Tester across the battery terminals and observe the reading. Compare the reading obtained with the following table to determine battery’s state of charge. Stabilized Open Circuit Voltage State of Charge 12.6 or more 12.4 12.2 12.0 11.7 or less Fully Charged 75% Charged 50% Charged 25% Charged Discharged 3.

If the stabilized voltage is at least 12.4 volts or higher, the battery is OK. 4. If stabilized voltage is below 12.4 volts, recharge the battery. Inspect the electrical system to determine the cause for the under-charged battery. 3-69