Komatsu — PPC CIRCUIT STRAINER

MAINTENANCE * The type of lubricant used depends on the ambient temperature. Select according to the table entitled “LUBRICANTS, FUEL AND COOLANT”. 9. Bleed the air from the hydraulic tank as described under “HYDRAULIC TANK’ in this section. Lower the bucket horizontally to the ground and stop the engine. IO. Check that there is no oil leaking at the oil drain plug and valve and the filter covers. 11. Check the oil level and ensure that it is correct. For the procedure, refer to “HYDRAULIC TANK OIL LEVEL” in this section. HYDRAULIC TANK BREATHER A WARNING! When removing oil filler cap (F), turn it slowly to relieve inner pressure. I. Remove oil filler cap (F). 2.

Remove the snap ring on breather (I), then remove the breather cap. 3. Replace the filter element with a new part, then install the breather cap and snap ring. * It is possible to replace the filter element with the breather installed in the tank. However, if the breath- er is removed, do not wrap the tapered thread of the breather with seal tape when reinstalling the breather. Also, be careful not to over tighten it. PPC CIRCUIT STRAINER The PPC circuit strainer is located on the rear frame near the brake oil tank at the rear of the cab. Clean the strainer as follows: Loosen the three case mounting bolts (1). Remove strainer case (2) and pull out the strainer.