Komatsu — MAIN CIRCUIT BREAKER

OPERATION AIR CLEANER SERVICE INDICATOR This device indicates clogging of the air cleaner element. When the YELLOW piston appears in the transparent part of the indicator, all the way up to the red line (1) then, the element is clogged. Immediately clean or replace the element. After cleaning or replacing the element, push indicator reset button (2) to return the yellow piston to its original position. 0 1 The service indicator is located on the front side of the engine hood behind the operators compartment. L12AR074 FRAME LOCKING BAR The frame locking bar is used during maintenance or when transporting the machine.

It locks the front frame and rear frame, and prevents the front and rear frames from moving at the articulation point. A WARNING! Always use the locking bar for maintenance or when transporting the ma- chine. WARNING! Always remove the locking bar during normal travel operations. A YV LOQAH018 MAIN CIRCUIT BREAKER The circuit breaker prevents damage to the electrical components and wiring. When the breaker has been actuated, press the reset button to reset the system. However, if the circuit breaker is actuated again after the button is pressed, or the circuit breaker is frequently actuated, there may be a short circuit in the electrical system.

In such cases, contact your distributor for repairs. * Wait for 45 seconds after the circuit breaker is actuated before resetting it. I/ \ LOSCHOW 2-28