Komatsu — 1000 HOURS LUBRICATION AND MAINTENANCE CHECKS

OM4036 Lubrication & Service - Section 40 Page 40-13 1000 HOURS LUBRICATION AND MAINTENANCE CHECKS Maintenance for every 10, 250, & 500 hour Lubrication and Maintenance Checks should be performed at this time. NOTE: “Lube Key” references are to the Lubrication Chart. 1. 2. 3. 4. 5. 6. FIGURE 40-8. AUXILIARY BLOWER 1. Grease Zerk 2. Auxiliary Blower Truck Serial Number Site Unit Number Date ______________________ _______________ _______________ Hourmeter Name of Service Technician _____________ ___________________________________ TASK COMMENTS CHECKED INITIALS HYDRAULIC TANK - Drain the hydraulic tank and clean the inlet strainer. Refill the tank with oil; approx- imate capacity 250 gal.

(947 l). Use Lube Key “B”. RADIATOR - Clean the cooling system with a quality cleaning compound. Flush with water. Refill the sys- tem with anti-freeze and water solution. Check the Cooling System Recommendation Chart in this sec- tion for the correct mixture. Refer to the Cummin’s Operation and Maintenance Manual for the correct additive mixture. FUEL TANK - Remove the breather and clean in sol- vent. Dry with pressurized air and reinstall. OPERATOR'S SEAT - Apply grease to the slide rails. Lube Key “D”. AUTOMATIC BRAKE APPLICATION - Ensure the brakes are automatically applied when brake pres- sure decreases below the specified limit. Refer to Section J, Brake Check-out Procedure.

AUXILIARY BLOWER - Apply a few applications of grease to the auxiliary blower bearings. Two grease zerks (1, Figure 40-9) are located on blower (2).