Komatsu — OPERATIONS AND CHECKECKS AFTER STARTING ENGINE

I OPERATION OPERATION I 0 Do not run the engine at low idling or high idling continu- ously for more than 20 minutes. This will cause leakage of oil from the turbocharger oil supply piping. If it is necessary to run the engine at idling, apply a load from time to time or run the engine at a mid-range speed. After starting the engine, do not immediately start operations. First, carry out the following operations and checks. 1. Turn fuel control dial (1) to the center position between LOW IDLING (MIN) and HIGH IDLING (MAX) and run the engine at medium speed for about 5 minutes with no load.

While running the engine at medium speed (A), press working mode switch (2) until the heavy-duty operation mode lamp is turned on. 1 MIN AM090410A 2. I ' 0 0 0 0 0 ' H/O GI0 F/O UO BIO I A AD157770A I 3. Set the safety lock lever to the FREE position, and raise the bucket from the ground. 4. Operate bucket control lever (5) and arm control lever (4) slowly to move the bucket cylinder and arm cylinder to the end of the stroke. (B) OUT I (D) DUMP AM090440A 105