MAINTENANCE 24.2.2 SERVICING THE DRIVE TRAIN SUCTION STRAINER 1. Remove the operators compartment floor board to locate the strainer. 2. Remove the four bolts (2) and separate the housing (6) from the base (1). Remove the element (4) with o-ring (5). 3. Wash the element and housing in a commercial solvent and dry thoroughly. Replace o-rings (3 and 5). Remove all dirt from the inside of the base using a cloth dampened with solvent. 4. Check that the new o-ring (5) is in place in the groove in the element (4). Slip the non o-ring end of the element into the housing. Secure the housing to the base (1) with the hardware previously removed. 5.
Start the engine and let it idle for approximately five minutes. During this time, check the strainer for leaks. Correct all leaks no matter how minor. Then check the level in the drive train system. Reinstall the operators compartment floor board. + For details of the fluid to use, see 20 USE OF FUEL, COOL- ANT AND LUBRICANT ACCORDING TO AMBIENT TEMPER- ATURE on page 3-8. 3-28