Komatsu — 24.10.1 CLEAN AIR CLEANER ELEMENTS

MAINTENANCE INSTALLATION 1. Insert the open end of the primary element (4) into the air cleaner body and secure with the wing nut and gasket (3). Install the cover (2) onto the air cleaner body. Secure with the wing nut (1) making sure the cover is not cocked. 2. Inspect and tighten all air cleaner connections before resuming operation. Start the engine. If the air cleaner filter service light continues to show air flow restriction, replace the primary or primary and safety filter element. Safety Filter Element I SERVICE Replace the safety element with every third change of the primary element or when plugged, as shown by the service light. REMOVAL 1.

Remove the primary filter element, See 24.10.1 PRIMARY FILTER ELEMENT on page 3-51. 2. Remove wing nut with gasket (1) and remove the safety element (2). Clean the inside of the body with a damp cloth. Check the condition of the gasket on the end of the safety element. If the gasket is damaged or missing, replace the element. 3-54