Komatsu — 15.3 AFTER STORAGE

15. LONG TERM STORAGE (MORE THAN ONE MONTH) 15.1 BEFORE STORAGE a WARNING I If possible, prepare the machine for long term storage outdoors. If this must be done indoors, open doors and windows for ventilation to prevent carbon monoxide poisoning. When putting the machine in storage for a long time, do as follows: After every part is washed and dried, the machine shall be housed in a dry building. Never leave it outdoors. In case it is necessary to leave it outdoors, park the machine on the flat ground and cover it with canvas etc. Completely fill the fuel tank, lubricate and change the oil before storage.

Apply a thin coat of grease to metal surface of the hydraulic piston rods and the idler adjusting rods. Disconnect the negative terminals of the battery and cover it, or remove it from the machine and store it separately. If the ambient temperature is expected to drop below 0°C (32”F), always add antifreeze to the coolant. Place the safety lock lever in the ON, locked (downward) position and place the fuel control lever in the low idling position. Do not lock the brake pedal; use blocks to stop the machine from moving.

15.2 DURING STORAGE + Operate the engine and move the machine for a short distance once a month so that a new film of oil will be coated over movable parts and component surfaces. At the same time, also charge the battery. + Before operating the work equipment, wipe off the grease on the hydraulic piston rod. 15.3 AFTER STORAGE NOTICE If the machine is stored without carrying out the monthly rust prevention operation, request your distributor for service. Carry out the following procedure when taking the machine out of long term storage: + Wipe off the grease from the hydraulic cylinder rods. + Add oil and grease to all places. 2-59