Assembly Procedure PC8000 Testing of the electrical function 1. Insert the battery in the test module and in the central unit; 2. Connect the test module with the actuator cable of the central unit; 3. Open the dash board and bridge the terminals X1C.92 and X1C.93 (that imitates a closed temperature sensor); 4. Put the three-position slide switch located on the left side of the test module in the upper position (“gas motor”). 5. Depress the “Reset” button on the tester. This will illuminate the “ready LED” if it is not already illuminated. 6. Once the unit activates, the unit tester will indicate a ”Pass” or “Fail” status resulting from the test. 7.
Remove the bridge at terminals X1C.92 and X1C.93. Placing the system in the service ) The activating of the system has to be carried out after the testing of the electrical function. 1. Insert the three LT-10-R Cartridges (one in the strike button at the power house door for manual actuation; one in the strike button in the operators cab for manual actuation and one in the automatic actuator in the operators cab). 2. Connect the actuator cable with the central unit. 3. Connect the extinguishing gas hose with the gas steel cylinder. B – Checkfire SC-N electric detection and warning system (Z23014) Assembling procedure: 1.
Connect the lines “1” and “2” coming from the machinery house in the cab support with the ports X2V.4 and X2V.5. Testing of the electrical function 1. Insert the battery in the central unit; 2. Open the dash board and bridge the terminals X1C.83 and X1C.84 (that imitates a fire in the machinery house); 3. If the horn sounds, remove the bridge of the ports at the dash port. PC8000AS rev 02.doc 149 Edition 01/2004