OPERATION 16.5.2 PRECAUTIONS FOR CHARGING BATTERY Charging Battery When Mounted on Machine ! Before charging, disconnect the cable from the negative terminal of the battery. Otherwise, an unusually high voltage will damage the alternator. ! While charging the battery, remove all plugs for satisfactory ventilation. To avoid gas explosions, do not bring fire or sparks near the battery. ! If the electrolyte temperature exceeds 45 E C(113 E F), stop charging for a while. ! Turn off the charger as soon as the battery is fully charged. Overcharging the battery may cause the following: 1) Decrease the quantity of electrolyte. 2) Damage the electrode plate. !
Do not mix the cables, positive (+) to negative (-) or negative (-) to positive (+), as it will damage the alternator. ! When performing any service to the battery besides checking the electrolyte lever or measuring the specific gravity, disconnect cables from the battery. 16.5.3 STARTING ENGINE WITH BOOSTER CABLE When starting the engine with a booster cable, do as follows: WARNING ! Precautions when connecting and disconnecting booster cable ! When connecting the cables, never contact the positive (+) and negative (-) terminals. ! When starting the engine with a booster cable, always wear safety glasses. ! Be careful not to let the normal machine and problem machine contact each other.
This prevents sparks from generating near the battery which could ignite the hydrogen gas given off by the battery. If hydrogen gas explodes, it could cause serious injury. ! Make sure that there is no mistake in the booster cable connections. The final connection is to the revolving frame, but sparks will be generated when this is done, so connect to a place as far as possible from the battery. (However, avoid connecting the cable to the work equipment, as connection is poor.) ! Use care when removing the cables from the machine that has been started. Do not allow the cable ends to contact each other or the machine, to avoid hydrogen explosion. 2-103