Komatsu — 16.6.3 ENGINE

OPERATION 16.6.3 ENGINE 2-107 Problem Main Causes Remedy Engine oil pressure monitor illuminates • Engine oil pan level is low, sucking in air • Clogged oil filter cartridge • Defective tightening of oil pipe joint, oil leakage from damaged parts • Defective engine oil pressure sensor • Defective monitor • Add oil to specified level; See 24.3 CHECK BEFORE STARTING on page 3-43 • Replace cartridge; See 24.5 EVERY 250 HOURS SERVICE on page 3-50.

• (Check, repair) • (Replace sensor) • (Replace monitor) Steam is emitted from top part of radiator (pressure valve) • Coolant level low, leakage • Loosen fan belt • Dirt or scale accumulated in cooling system • Clogged radiator fin and/or damaged fins • Defective thermostat • Loose radiator filler cap (high altitude operation) • Defective coolant level sensor • Defective monitor • Add coolant, repair; See 24.3 CHECK BEFORE STARTING on page 3-43 • Adjust fan belt tension; See 24.5 EVERY 250 HOURS SERVICE on page 3-50. • Change coolant, clean inside of cooling system; See 24.2 WHEN REQUIRED on page 3-24 • Clean or repair; See 24.6 EVERY 500 HOURS SERVICE on page 3-55.

• (Replace thermostat) • Tighten cap or replace packing • (Replace sensor) • (Replace monitor) Radiator coolant level monitor illuminates Engine does not start when starter motor is turned • Lack of fuel • Air in fuel system • Defective fuel injection pump or nozzle • Starter motor cranks engine slug- gishly • Preheat monitor does not illumi- nate • Defective compression (Valve clearance) • Add fuel; See 24.3 CHECK BEFORE STARTING on page 3- 43 • Repair place where air is sucked in; See 24.6 EVERY 500 HOURS SERVICE on page 3-55.

• (Replace pump or nozzle) • See 16.6.1 ELECTRICAL SYSTEM on page 2-105 • See 16.6.1 ELECTRICAL SYSTEM on page 2-105 • (Adjust valve clearance) Exhaust gas is white or blue • Too much oil in oil pan • Improper fuel • Add oil to specified level; See 24.3 CHECK BEFORE STARTING on page 3-43 • Change to specified fuel