MAINTENANCE Wear eye protection when using air under pressure to clean parts. Limit air to less than 7 kg/cmІ (100 psi). WARNING 3. Direct dry compressed air to element (6) from inside along its folds, then direct it from outside along its folds and again from inside. a) Remove one seal from the outer element (1) whenever the outer element has been cleaned. b) Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element (4) at the same time. c) Replace both inner and outer elements when the monitor lamp flashed soon after installing the cleaned outer ele- ment even though it has not been cleaned 6 times.
d) Check inner element mounting nut for looseness and, if necessary, retighten. Hex nut (6) . . . . . . . . . . . . . . . . . . . . . . . . . 4.9 to 5.9 N C m e) If seal washer (2 or 7) is/are damaged or the thread of nut (3 or 6) is/are broken, replace with a new part/s. f) Remove vacuator valve (10) and clean with compressed air. 1. Outer element 7. Nut seal 2. Nut seal 8. Cover gasket 3. Wing nut 9. Snap ring 4. Inner element 10. Vacuator 5. End cover 11. Wing nut 6. Hex nut 12. Housing 4. If small holes or thinner parts are found on the element when it is checked by shining a light through it after cleaning, replace the element. 3-25