Komatsu — 24.5.3 REPLACE HYDRAULIC FILTER ELEMENT

MAINTENANCE 24.5.3 REPLACE HYDRAULIC FILTER ELEMENT WARNING When removing the oil filler cap, turn it slowly to release the internal pressure before removing it. 1. Remove the cover over the hydraulic tank. 2. Remove the oil filler cap (A), to release the internal pressure. 3. Loosen (4) bolts, then remove cover (1). When doing this, the cover may fly out under the force of spring (2), so hold the cover down when removing the bolts. 4. After removing spring (2) and valve (3), take out element (4). 5. Clean all the removed parts in diesel oil. 6. Install a new element in the place where old element (4) was installed. 7. Set valve (3) and spring (2) on top of the element. 8.

Set cover (1) in position, push it down by hand, and install the cover with the mounting bolts. 9. Mount the oil filler cap and install the cover. 10. To bleed the air, start the engine according to See 12.2 STARTING ENGINE on page 2-54.and run the engine at low idle for 10 minutes. 11. Stop the engine. REMARK After halting work, operate the machine for more than 5 minutes to eliminate air bubbles in the oil inside the tank. 12. Check for oil leakage and wipe off any spilled oil. When the hydraulic breaker is installed, the hydraulic oil deteriorates earlier than in normal bucket digging work. The first element replacement should be at 100 to 150 hours for new machines.

Thereafter, replace the element according to the table on the right. Replace the additional filter element for the breaker every approx. 250 hours (when breaker operating ratio is more than 50%) according to the table on the right. 3-51