MAINTENANCE BLEEDING THE FUEL SYSTEM Controlled venting is provided at the injection pump through the fuel drain manifold. Small amounts of air introduced by chanting the filters or injection pump supply line will be vented automatically if the fuel filter is changed in accordance with the instructions. However, manual bleeding will be required if: ! The fuel filter is not filled prior to installation. ! The injection pump is replaced. ! The high pressure fuel lines are replaced. VENTING THE LOW PRESSURE LINES AND FUEL FILTER 1. Loosen the bleed screw. (wrench size: 10mm) 2. Operate the hand lever on the lift pump until the fuel flowing from the fitting is free of air. 3.
Air/fuel can be pumped from this location with the hand lever on the lift pump if the fuel solenoid valve is energized. 4. Air can be vented from both pumps through the fuel drain manifold by operation the starting motor. When using the starting motor to vent the system, do not engage it for more than 30 seconds at a time; wait (2) minutes between engagements. WARNING It is necessary to put the engine in the “RUN” position. Because the engine may start, be sure to follow all the safety precautions. Use the normal starting procedure. VENTING THE HIGH PRESSURE LINES Loosen the fittings at the injectors and crank the engine to allow entrapped air to bleed from the lines.
Tighten the fittings to 30 N C m (22 lbf ft)(wrench size: 17 mm). CAUTION: High pressure can cause penetration of skin. WARNING Do not bleed a hot engine as this could cause fuel to spill onto a hot exhaust manifold creating a danger of fire. Start the engine and vent one line at a time until the engine runs smoothly. 3-56