OPTIONS, ATTACHMENTS 30.1.6 ACCUMULATOR WARNING The accumulator is charged with high pressure nitrogen gas, and it is extremely dangerous if it is handled mistakenly. For details; See 11.22 HANDLING ACCUMULATOR on page 2-42. This is installed to release any remaining pressure in the attachment circuit after the engine is stopped. Normally, do not touch it. 30.2 HYDRAULIC CIRCUIT 30.2.1 SWITCHING TO FILTER CIRCUIT When a breaker or general attachment (such as a crusher) are used, set Left and right 3-way valves (1) and (2) as follows.
Referring to the following chart, turn the rotors fo left and reght 3- way valves (1) and (2) using a wrench to select the attachment to be mounted and the direction of both 3-wat valves. (The arrows indicating the port direction are stamped on the 3-way valve heads.) ! When the machine is equipped with the breaker, connect the return circuit directly to the return filter. ! The standard set pressure for the low pressure safety valve is 210 kg/cmІ (2990 psi) when shipped from the plant. ! When installing breakers made by other manufacturers, it is necessary to adjust the pressure, so please contact your distributor.
5-11 Attachments Left valve (1) Right valve (2) Breaker Forward direction of machine Machine Left 7L Right Crusher etc. Forward direction of machine Machine Left 7L Right When not in use Forward direction of machine Machine Left 7L Right