Komatsu — 11.2.13 SWING LOCK OVERRIDE SWITCH

OPERATION 11.2.12 PUMP CONTROL OVERRIDE SWITCH When normal: Switch is pushed down When abnormal: When the monitor display shows E02 (PC-EPC valve system error), move the switch up to make it possible to carry out work. The pump control override switch is provided to make it possible to carry out work for a short time when there is a failure in the pump control system (PC-EPC valve system error). It is necessary to repair the abnormal location immediately. 11.2.13 SWING LOCK OVERRIDE SWITCH When normal: Switch is pushed down When abnormal:

When the monitor display shows E03 (Swing brake system error), the brake is canceled, and it becomes possible to actuate the swing and carry out normal operations. However, the swing brake remains released. The swing lock override switch is provided to make it possible to carry out swing operations for a short time even when there is an abnormality in the swing brake electric system (Swing brake system error). It is necessary to repair the abnormality immediately. 2-18