3.4.12. Pressure limiter valve z The pressure limiter valve is at the connection end to the common rail, is closed by the cone shaped end of the plunger valve against inside of the valve body. At normal operating pressures (1600bar), a spring forces the plunger against the seat and the common rail remains closed. z As soon as the operating pressure is exceeded, the plunger is forced by the rail pressure against the force of the spring, the fuel pressure is maintained with the normal pressure, and the escape fuel return to the fuel tank through the return pipe. Valve Plunger Fuel return Common rail Valve spring Valve body 3.4.13.
Injector z The start of injection and the injected fuel quantity are adjusted by the solenoid valve of the injector. These injectors supersede the nozzle and nozzle holder of the existing engine. The fuel is fed from the high pressure connector, to the nozzle through the passage, and to the control chamber through the feed orifice. z The control chamber is connected to the fuel return via a bleed orifice which is opened by the solenoid valve. With the bleed orifice closed, the hydraulic force applied to the valve control plunger exceeds that at the nozzle needle pressure shoulder.
As a result, the needle is forced into its seat and seals off the high z When the injector's solenoid valve is triggered, the bleed orifice is opened. This pressure passage from the combustion chamber. leads to a drop in control-chamber pressure and, as a result, the hydraulic pressure on the plunger also drops. As soon as the hydraulic force drops below the force on the nozzle-needle pressure shoulder, the nozzle needle opens and fuel is injected through the spray holes into the combustion chamber. DL06 Diesel Engine Disassembly and Reassembly of Major Components 128