Komatsu — WHEN REQUIRED

WHEN REQUIRED Water filler Drain valves (radiator, oil cooler) Drain valve (cylinder block) 4. When the water reaches the vicinity of the water filler, put the engine at low idling, open drain 5. When the water becomes com- pletely clean, stop the engine, draining off the cooling water, and close drain valves (3), (4) and (5). After draining the water, clean with a cleaning agent. We recommend use of a Komatsu genuine cleaning agent. For details of the cleaning method, see the instructions given with the cleaning agent. After cleaning, drain all the cool- ing water, then close the drain valves (31, (4) and (51, and fill slowly with soft water.

When the soft water comes up to near the radiator water filler port, start the engine, and run at low idling. Add soft water, open drain valves (3). (4) and (51, and continue to run water until clean colorless water comes out from the drain valves (31, (4) and (5). When doing this, adjust the speed of filling and draining the water so that the radiator is always full. valves (31, (4) and (51, then pass water for 10 minutes through the cooling system until clean water comes out from drain valves (3), (4) and (5). When doing this, adjust the speed of filling and draining the water so that the radiator is always full. 6. * * - 106 - h-04316