Sauer-Danfoss — SECTION2HYD_DRIVE.qxp

DRIVE MOTOR 2.11 Removal 12 Remove the jam nuts, mounting nuts and lock wash- ers from the 4 mounting bolts retaining the drive motor to the final drive housing. (fig. C3491) Hold the head of the bolts from inside the final drive housing. (fig. C3492) 13 Remove the drive motor. Seal the drive motor with silicone upon reassembly. 14 Upon reassembly torque the 4 mounting nuts to 80 lbs / ft. 15 If the drive motor replacement is being performed because of major parts failure, such as geroter damage, the hydraulic system must be checked for contamination and flushed if necessary as outlined in Section 2.7.

Nuts 2 C3491 Torque motor mounting bolt C3492 16 If you are installing a new drive motor, remove the drive motor sprocket and bolt if you wish to reuse the sprocket. (fig. C3493) Drive sprocket C3493 17 Install the sprocket, machined washer, lock washer and bolt. Apply Loctite 242 (blue) to the threads of the bolt before torquing (fig. C3767) and torque the bolt to 40 lbs / ft. (54 nm). Apply loctite C3767 2-29