MAINTENANCE PLAN 4.7.10 MAINTENANCE AFTER THE FIRST 500 HOURS OF OPERATION (Only for machines in which the synthetic biodegradable oil type HEES is used) The following maintenance operation must be carried out after the first 500 hours of operation, together with the maintenance operations to be carried out “EVERY 500 HOURS”. HYDRAULIC OIL CHANGE AND SUCTION FILTER CLEANING For further details on the various maintenance operations, see section “EVERY 2000 HOURS”. 4.7.11 MAINTENANCE EVERY 500 HOURS OF OPERATION These operations must be carried out together with those to be carried out EVERY 50, 100 and 250 HOURS.
168 • Soon after the machine has been stopped the hydraulic oil is very hot; let it cool down until it reaches a temperature of 40-45°C before changing it. • The hydraulic system is pressurized; loosen the filling cap slowly to release the residual pressure. • Oils, filters, coolants and batteries are considered special waste and must be collected and disposed of according to the anti-pollution regulations in force. CAUTION • On new machines, change the hydraulic oil filter cartridge after the first 250 hours of operation and successively eve- ry 500 hours.
• On machines in which the synthetic biodegradable oil type HEES is used, the first change must be carried out after the first 50 hours of operations and the successive ones every 500 hours. The filter is positioned on the hydraulic system drain outlet and blocks the metal particles that come off the various components due to their wear. The filter can be reached by opening the right side cover (see “3.5.2 SIDE COVER”); to change it, proceed as follows: 1 - Slowly loosen the filling cap (1) in order to release the residual pressure from the tank and then remove it.