Komatsu — 4.7.11.a CHANGING THE HYDRAULIC SYSTEM OIL FILTER

MAINTENANCE PLAN 169 2 - Remove the screws (2) that hold the filter cover (3), remove the cartridge (4) and the filter casing (5). Use a 13 mm spanner. 3 - Carefully clean the filter casing (5), making sure that the filter gasket (7) and the container gasket (8) are in perfect condi- tions. 4 - Change the cartridge (4). 5 - Reassemble all the components proceeding in the reverse or- der and making sure that the gasket (6) of the cover (3) is sound and correctly positioned in the cover seat. 6 - Close the side cover.

2 3 6 4 7 8 5 RYA14480 2 3 6 4 7 8 5 RYA14480 IMPORTANT • The hydraulic oil used in machines provided with demoli- tion hammer deteriorates sooner than the oil used in ma- chines that carry out only normal digging operations. On new machines the filter must be changed after the first 100-150 hours of operation, while the successive changes must be carried out according to the intervals indicated on table beside. • If the machine contains synthetic biodegradable oil type HEES, the filter must be changed after the first 50 hours of operation.

Replacement interval 800 for element Replacement (H) 500 interval 100 0 20 40 60 80 100 Breaker operating ratio (%) RWA10710 Replacement interval for element