. OPERATION OPERATION GAUGE PANEL SPEC into starting switch (2), turn the key of starting switch (2) to the HEAT position and hold it until glow signal (3) 3 - 67 NOTICE Do not start the engine with the fuel control lever near the FULL . It may lead to damage of the engine parts. D start the position . It may le ad to d amage of the e ngine parts. Do not k seconds eep the starting motor rotating continuously for more than 20 . If the en gine fails to start, repeat steps 3 and 4 after waiting for about 2 minutes . 1. Befor e starting the e ngine, c heck t hat fu el control leve r (1) is at t he lo w idling positio n. 2.
Pull fu el contro l lever (1) to a position mi dway betwee n the l ow i dling and full speed positio ns. 3. I nsert the key switch (2) The pre-heating ti mes ar e as sh own b elow. Ambient temperature Preheat time 0°C to -5°C (32°F to 23°F) - -5°C to -10°C (23°F to 14°F) 15 seconds -10°C to -20°C (14°F to -4°F) 30 seconds -20°C to -30°C (-4°F to -22°F) 45 seconds