ELECTRICAL RPM CONTROL Circuit Configuration 1. Work mode switch 2. Instrument panel 3. Main controller 4. Proportional solenoid 5. Throttle driver 6. Engine 7. Throttle motor 8. Power Boost solenoid Values set for each mode Note: Shown above are for normal conditions; except the following exceptions: 1. In “L” mode if travel only is actuated, the pump is controlled by the value of “S” mode current. 2. In “L” mode if a hydraulic hammer is used, the pump is controlled by the value of “S” mode current.
4 - 13 CX EXCAVATORS Mode Item CX130 CX160 Power Boost H MODE Engine rpm (max) 2470 ± 10 2470 ± 10 One-Touch Power Boost mA Current (max) 600 600 mA Current (min) 550 510 S MODE Engine rpm (max- 200) 2270 ± 10 2270 ± 10 One-Touch Power Boost mA Current (90% of torque) 550 510 L MODE Engine rpm (max- 300) 2170 ± 10 2170 ± 10 Constant mA Current (70% of torque) LOW IDLE Engine rpm (max) 950 ± 10 950 ± 10