ELECTRICAL RPM CONTROL Circuit Configuration 1. Proportional solenoid 2. Power boost solenoid 3. Main controller 4. Engine controller 5. Engine 6. Electronic injection pump Values set for each mode Values set for each model Note : Shown above are for normal conditions; except the following exceptions: 1. In “L” mode if travel only is actuated, the pump is controlled by the value of “S” mode current. 2. In “L” mode if a hydraulic hammer is used, the pump is controlled by the value of “S” mode current.
4 - 15 CX EXCAVATORS Mode Item CX210 CX240 Power Boost H MODE Engine rpm (max) 2000 ± 10 2200 ± 10 Automatic Power Boost mA Current (max) 407 424 mA Current (min) 292 307 S MODE Engine rpm (max- 200) 1800 ± 10 2000 ± 10 Automatic Power Boost mA Current (90% of torque) 292 307 L MODE Engine rpm (max- 300) 1700 ± 10 1900 ± 10 Constant mA Current (70% of torque) LOW IDLE Engine rpm (max) 900 ± 10 900 ± 10