ce t — cxsec6.pdf

HYDRAULICS – CX210/CX240 6 - 4 CX EXCAVATORS FEATURES Operation Function Explanation Automatic Power Boost 1) When main pump pressure reaches approximately 4350 psi and the load ratio fluctuation of the engine is ±5% for two seconds. The controller will energize the power boost solenoid and increase main relief approximately 8%. 2) This power boost increase will occur for 8-second intervals. 3) Power boost is on full time in L mode. See pages 38-39 Main Relief Valve The Main Relief has two adjustments:

1) Standard Main Relief pressure 2) Power Boost Pressure See pages 40-41 Neutral Pump Destroke (negative flow control) 1) If the flow output of pump1 or pump2 is not needed the output is kept at a minimum flow rate (negative control flow rate), and energy consumption is reduced. See pages 42-43 Free Swing Operation 1) An orifice leak is opened between the A and B ports of the swing motor. This will provide smoother starts and stops of the swing during hoisting operations. See pages 44-45 OPTIONS Operation Function Explanation Auxiliary hydraulic kits There are three auxiliary hydraulic options.

1) Hammer kit (one direction, one pump flow) 2) Multi-kit (two direction or one direction flow, one pump or two pump flows) 3) Thumb kit (two direction one pump flow) See pages 46-47