HYDRAULICS – CX210/CX240 6 - 3 CX EXCAVATORS ATTACHMENT Operation Function Explanation Boom Raise 1) Two pump flows inside the control valve are combined, when the boom1 and boom2 control spools are shifted. See pages 24-25 Boom Lower 1) When a built-in anti-drift valve in the control valve is opened and boom1 spool is shifted, the boom can be lowered. 2) A regeneration valve inside the boom1 control spool provides additional speed. 3) Only one pump flow is used. See pages 26-27 Arm Open (Out) 1) Two pump flows inside the control valve are combined, when the arm1 and arm2 control spools are shifted.
See pages 28-29 Arm Close (In) 1) When a built-in anti-drift valve in the control valve is opened and arm1 spool is shifted, the arm can be closed. 2) Two pump flows inside the control valve are combined, when the arm1 and arm2 control spools are shifted. 3) A regeneration valve provides additional speed. See pages 30-31 Cushion “ON” Operation (Boom & Arm) 1) As a control spool returns to neutral (center) position, the pilot oil must return through an orifice in the cushion valve. 2) The slow movement of the spool provides the cushion feature. 3) The Cushion only occurs in the boom and arm circuits.
See pages 32-35 Cushion “OFF” Operation 1) When the cushion solenoid is energized pilot pressure is sent to the cushion valve, the orifices are shifted out of the circuit and the cushion feature will not function. See pages 36-37