CX210/CX240 ELECTRONIC FUEL SYSTEM 8 - 24 CX EXCAVATORS FAULT CODE LISTING Fault Associated Hardware Reason Effect (only with active code) F441 Battery voltage low Voltage detected at ECM power supply, pins 38, 39 and 40 of the engine harness indicates voltage is below 6 VDC. Engine will stop running or run rough. F442 Battery voltage high Voltage detected at ECM power supply, pins 38, 39 and 40 of the engine harness indicates voltage is above the maximum voltage. No effect on engine performance. F443 Accelerator pedal position sensor. Low voltage detected at throttle position sensor +5 VDC supply pin 29 of the OEM harness.
Engine idles when idle validation switch indicates idle and ramps up to a default set speed when validation indicates off idle. F488 Intake air temp sensor/ EPF Intake manifold air temp signal indicates intake temp. above minimum engine protection threshold. Power de-rate and possible engine shut down. F517 Fuel pump control valve is mechanically stuck. A mechanically stuck control valve has been detected. Engine may shut down. F524 High speed governor droop selection switch. Error detected in selector switch at pin 24 of engine harness. Operator can not select alternate HSG group. Normal droop is used. F611 Hot shut down error.
ECM detected the engine has initiated a protection shut down or has been keyed off while above a specified load limit. No effect.