CONTROLLER CURRENT CONDITION CHK2 CHK MODE 2 H 2 % F % R: Engine Load Ratio (CX210/CX240) FT: Fuel Temperature (CX210/CX240) TV: Throttle Volume TR1: Transistor Output TR2: Transistor Output TR3: Transistor Output TR4: Not Used Engine Load Ratio ((Q-Qn) / (Qf-Qn)) Fuel Flow: Q – Current Qn – No Load Qf – Maximum Flow R: CX210/CX240 Information sent from the engine controller to the main controller. The main controller uses this information for recording purposes. The controller also uses this information plus pump pressure to determine when to activate Auto Power Boost. FT: CX210/CX240 Information sent from the engine controller to the main controller.
The main controller uses this information for recording monitoring purposes. TV: Use this field to verify that the controller is receiving the signal from the throttle control knob. TR1, TR2, TR3: These fields can be used to verify that the controller is sending the signal to turn these various circuits on and off as they are selected by the operator. 3 - 14 CX EXCAVATORS TR1 0 0 0 0 R 0 0 0 0 TR2 0 0 0 0 FT 0 0 0 0 TR3 0 0 0 0 TV 0 0 0 0 TR4 0 0 0 0