International Trucks — International VT 365 Diesel Engine Service Manual 2004-2006

66 ELECTRONICALLY CONTROLLED VARIABLE GEOMETRY TURBOCHARGER (VGT) Check Free Rotation and Housing Rub go. Put tip of dial indicator (Table 6) on end of the compressor side of the shaft and zero the indicator. 1. Put VGT on a bench with the shaft in a horizontal position. Figure 64 Axial end play 1. Dial indicator with magnetic base 2. Compressor housing Figure 63 Free rotation of VGT shaft 2. Turn VGT shaft by hand; the shaft must spin freely. Contact with the turbine and compressor housings is not acceptable. 2. Move shaft back toward the dial indicator. 3. If measurement exceeds specifications, (Table 4) replace VGT. Check Axial End Play 1.

With VGT in a stable position, push the impeller shaft toward the turbine housing as far as it will EGES295-2 Read all safety instructions in the "Safety Information" section of this manual before doing any procedures. Follow all warnings, cautions, and notes. ©2006 International Truck and Engine Corporation