92 MANIFOLDS AND EXHAUST GAS RECIRCULATION (EGR) Left Exhaust Manifold Figure 122 Mounting bolts for right exhaust tube 5. Apply anti-seize compound to two M8 x 60 bolts securing the right exhaust tube assembly to the exhaust manifold flange with two prevailing torque nuts. Loosely assembly bolts and nuts. Figure 124 Bolt and spacer for left exhaust manifold 1. Anti-seize compound 1. Apply anti-seize compound to all bolt threads. 2. Position exhaust manifold gasket. 3. Install left exhaust manifold, using eight M8 x 40 prevailing torque hex flange bolts and spacers. Start with the second bolt from the rear on top. The hole diameter is smaller, to allow alignment of the remaining bolts. 4.
Tighten bolts to specified torque (Table 8) and in the specified sequence (Figure 121). Figure 123 EGR cooler V-clamp 6. Install steel gasket for EGR cooler. 7. Attach right exhaust tube assembly to EGR cooler assembly with V-clamp. Do not tighten V-clamp. Figure 125 EBP sensor tube fitting EGES295-2 Read all safety instructions in the "Safety Information" section of this manual before doing any procedures. Follow all warnings, cautions, and notes. ©2006 International Truck and Engine Corporation