DRESSTA Co. Ltd. TD-40C98/1E — 4.7. STARTING THE ENGINE

OPERATING SECTION 4 Page 21 STARTING THE ENGINE 4.7.2. ETHER INJECTOR START (temperatures below 0°C) WARNING! Ether starting fluid is highly flammable. Follow the precautions on the container. An explosion can result if sparks or flame contact the ether or when storing ether container when the air temperature is above 70°C. Observe the following precautions: Do not use the ether injector when the air temperature is above 0°C. Do not use open flame when using ether starting fluid. Do not store fluid containers in the operator's compartment. Store the containers in a cool, well ventilated place. Keep the fluid containers out reach of children. Do not breathe the hazardous ether vapor.

Do not let ether contact you skin, because it can cause frostbite. Never puncture the fluid container or put it into a fire Dispose of empty containers per instructions printed on the container For your safety, remove the ether container when welding, grinding, or using a torch on the machine. Follow the correct method for starting the engine. Before any attempt to start the engine, check the ether container or insure that a supply of starting fluid is available under pressure and the system is in working condition. Pressing the switch in the instrument panel makes ether injection. WARNING! Ether injector is to be used only for starting.

Misuse of ether injector while engine is running can result in serious damage to engine. 1. Follow the steps described in the Items 1 through5. Refer to NORMAL START (temperature above 0°C). - Crank the engine - press the start switch button (KTA-19C engine) - turn the starting switch key to the right to the START position (QSK-19 engine) Press both the engine button and the ether injector switch simultaneously. Allow one to two seconds for chamber in the valve to fill in then, with the engine cranking, release the ether injector switch to inject a measured shot of starting fluid into the engine. If temperature is below –18°C, additional ether shots may be required.

If the engine does not fire with 4 injections maximum, determine the cause of the engine failure to start and correct it before any another attempt to restart the engine. IMPORTANT: Crank engine for 30 seconds at a time. If engine does not start, allow cranking motor to cool two or three minutes before cranking again. 4.7.3. ENGINE START AFTER OIL CHANGE OR PROLONGED STANDSTILL (over 5 days) 1. Follow the steps described in the Items 1 through 6. Refer to NORMAL START. 2. Shift the engine speed control lever to OFF position (Fig. 4.16). 3. 3. QSK-19 engine. Unplug the male part of the ESP engine RPM sensor connector. Refer to Fig. 16A. 4.

Crank the engine - - press the start switch button (KTA-19C engine) - turn the starting switch key to the right to the START position (QSK-19 engine) (Fig. 3B) Continue to crank the engine until oil gauge registers oil pressure or low oil pressure warning light goes off. DRESSTA TD-40C