SECTION 4 OPERATING Page 28 4.18. OPERATING MOUNTED EQUIPMENT General The hydraulic system provides power for the blade equipment, ripper or various other types of equipment. Specific instructions for the operation of the blade and ripper are included in this section. IMPORTANT: Holding a control lever in any position except HOLD or FLOAT for an extended period off time after the hydraulic cylinder rod has reached the limit of its travel will produce excessive heat in the hydraulic system which may affect equipment performance. Fig. 4.25. Blade Control Lever Positions I – Lower II - Hold III - Raise IV - LH Tilt V - RH Tilt 4.18.1.
HOLD When the lever is released from any position except “Float”, the lever automatically returns to the hold position. The blade height will remain the same, as it was when the lever was released. 4.18.2. RAISE Pull the control lever back to raise the blade to desired height. When released the lever will return to the hold position. 4.18.3. LOWER Push the control lever forward to lower the blade. When released the lever will return to the hold position. 4.18.4. FLOAT With the control lever in the float position, the blade is free to follow the contour of the ground. To place the control lever in the float position, push all the way forward to its detented position in direction I in Fig.25.
The lever will remain in this position until it is manually returned to the hold position. TD-40C DRESSTA